• S2E2: Marc and Mark: The New ISO 14644-21: 2023 Airborne Particle Sampling Techniques
    Sep 8 2023

    In Season 2, Episode 2 of the Marc and Mark Contamination Control Podcast, Marc Machauer and Mark Hallworth, particle monitoring experts at Particle Measuring Systems, discuss the new release of ISO 14644-21: 2023 Airborne Particle Sampling Technique. Mark Hallworth served on the ISO task force to rewrite this standard. They discuss behind-the-scenes stories from the writing of the new standard, including topics such as tubing length, isokinetic sampling, and best practices.

    Show More Show Less
    16 mins
  • S1E10: Marc and Mark: Retroactive Contamination Control Risk Assessments on Aseptic Fill Lines
    Dec 16 2022

    In Part 10 of this Limited Series from Particle Measuring Systems' contamination control experts Marc Machauer, Global OEM Business, and Mark Hallworth, Global GMP Specialist, discuss the topic of performing a retroactive Risk Assessment on existing fill lines as required by the release of EU GMP Annex 1 in August 2022. 

    Without measurement there is no control


    Do you have questions about today's topic?
    Our expert advisors are ready to help answer your questions. Find us on the Web at www.pmeasuring.com.

    Show More Show Less
    23 mins
  • S1E9: Marc and Mark - Environmental Monitoring During Toxic Product Manufacturing
    Dec 7 2022

    In Part 9 of this Limited Series from Particle Measuring Systems, contamination control experts Marc Machauer, Global OEM Business, and Mark Hallworth, Global GMP Specialist, discuss the unique environmental monitoring issues encountered when manufacturing products with high toxicity profiles. 

    Without measurement there is no control


    Do you have questions about today's topic?
    Our expert advisors are ready to help answer your questions. Find us on the Web at www.pmeasuring.com.

    Show More Show Less
    13 mins
  • S1E8: Marc and Mark - Support Areas Surrounding Aseptic Fill Lines
    Oct 19 2022

    In Part 8 of this Limited Series from Particle Measuring Systems, contamination control experts Marc Machauer, Global OEM Business, and Mark Hallworth, Global GMP Specialist, discuss the environmental classification, management, and effective monitoring of Grade B & C areas surrounding Isolator and RABS systems.

    Without measurement there is no control


    Do you have questions about today's topic?
    Our expert advisors are ready to help answer your questions. Find us on the Web at www.pmeasuring.com.

    Show More Show Less
    17 mins
  • Multi-Award Winning IsoAir Pro, Aerosol Particle Sensor - Discussion with Paul Hartigan
    Aug 16 2022

    In this interview, Blu Buquoy, Marketing Specialist and Paul Hartigan, Global Product Line Manager , sit down to discuss and compare the new IsoAir Pro E and IsoAir Pro Plus, Aerosol Particle Sensors that complete the Pro Product line at Particle Measuring Systems.

    Without measurement there is no control


    Do you have questions about today's topic?
    Our expert advisors are ready to help answer your questions. Find us on the Web at www.pmeasuring.com.

    Show More Show Less
    10 mins
  • The Biocapt Single Use - A dicsussion with Giulia Artalli
    Jul 7 2022

    In this interview, Blu Buquoy (Marketing Specialist) and Giulia Artalli (Product Line Manager at Particle Measuring Systems), sit down to discuss what makes the Biocapt Single Use the only solution for reliable and continuous active microbial monitoring.

    Without measurement there is no control


    Do you have questions about today's topic?
    Our expert advisors are ready to help answer your questions. Find us on the Web at www.pmeasuring.com.

    Show More Show Less
    7 mins
  • S1E7: Marc and Mark - Particle Counter Sample Tubing Concerns in Aseptic Manufacturing
    Oct 12 2022

    In Part 7 of this Limited Series from Particle Measuring Systems, contamination control experts Marc Machauer, Global OEM Business, and Mark Hallworth, Global GMP Specialist, discuss nonviable particle counter sample tubing concerns raised by the most recent EU GMP Annex 1 release. Their conversation includes how particles act in tubing, optimum tubing length, acceptable risk, and other variables contributing to obtaining effective and actionable particle counts in aseptic manufacturing.

    Without measurement there is no control


    Do you have questions about today's topic?
    Our expert advisors are ready to help answer your questions. Find us on the Web at www.pmeasuring.com.

    Show More Show Less
    15 mins
  • S1E6: Marc and Mark - Environmental Monitoring System Installation on Aseptic Fill Lines
    Sep 28 2022

    In Part 6 of this Limited Series from Particle Measuring Systems, contamination control experts Marc Machauer, Global OEM Business, and Mark Hallworth, Global GMP Specialist,  discuss environmental monitoring systems on aseptic fill lines and best practices for their installation to ensure accurate viable and nonviable particle monitoring. Their discussion includes considerations around vacuum systems, sample tubing, and ensuring monitoring flexibility. 

    Without measurement there is no control


    Do you have questions about today's topic?
    Our expert advisors are ready to help answer your questions. Find us on the Web at www.pmeasuring.com.

    Show More Show Less
    20 mins